Embedded Motion Control 2017 Group 9

From Control Systems Technology Group
Jump to navigation Jump to search

Group Members

Name: Student id:
Mian Wei X
Zhihao Wu X
Petrus Teguh Handoko X
Bo Deng X
Bo Cong X
Jian Wen Kok X
Nico Huebel Tutor


Initial Design

The initial design for the maze challenge is elaborated below. It includes the requirements, functions, components, schematic of program structure, specifications and interfaces to define the working of PICO. The file for the initial design is included here: File:Assignment-for-week1.pdf

Requirements

➢ PICO drives autonomously through maze
➢ Being able to take a turn without touching a wall
➢ Being able to detect a turn or branching corridors
➢ Avoiding collisions with obstacles (including the walls)
➢ Driving straight and rotating smoothly
➢ PICO should not stand still for 30 seconds
➢ Avoid getting trapped in a loop of the maze
➢ Being able to recognize the door

Functions

Functionsg9.jpeg

Components

drive control
‐Holonomic base (omni‐wheels)
‐Pan‐tilt unit for head

detection ‐170◦ wide‐angle camer
‐Laser Range Finder (LRF)
‐Wheel encoders (odometry)
‐Asus Xtion Depth sensor

world model
computer
‐Intel I7
‐Ubuntu 14.04

Specifications

- maximum translational speed of 0.5 m/s
‐ maximum rotational speed of 1.2 rad/s
‐ Door template: length of 0.5 ‐ 1.5m and with side walls of approximately 30cm, see figure below
‐ LRF accuracy and range unknown
‐ odometer accuracy unknown

Doortempg9.jpeg

Interfaces

The odometer and LRF generates data for mapping the environment.

The algorithm sets nodes on the junction as a setpoint for navigation, plans the route and put the actuators to work accordingly.

The odometer and LRF keeps on keeping track of the environment and the software recognizes obstructions, dead ends that might be doors and junction.

Corridor challenge

design

At first, PICO moves forward with a modified potential field.
When it detects the junction, the potential field goes off and stops when it is in the middle of the junction.
PICO then rotates 90 degree and moves forward.
When PICO detects that it is inside the junction, the potential field goes on and finishes the challenge.

result

The corridor challenge failed

In the first trial PICO moved straight forward without potential field.
When it detects the junction it stopped and rotated 90 degrees in the wrong direction.
This inevitably resulted into crashing into the walls.

The second trial PICO did not detect the junction and drove straight forward, this was the latest program.

evaluation

The first trial used our old program that has proven itself as seen in the video below. Unfortunately we did not push the correct version to PICO.
Corridor test.gif

The second trial used our latest program. Potential field is added because there exists a chance that PICO would run into the walls without it.
The new program works in the simulation, it has been tested in the real setting and we had problems with the odometer to correctly make the turning.
The program had to run without debugging in the real setting. Later on, a bug was found in the junction detection.

Maze challenge

design

architecture

Architecture.jpeg

main flow

Main flow.jpeg

detection

door detection

Door detection.jpeg

junction detection

In the following picture, it is clear that three laser bundles in forward, minus ninety degree and plus ninety degree are selected to detect the junction. In order to find junction in perfect way, the detection radius and detection angle need to be well calculated. The detection angle is set to be 24 since the maximum detection range is from minus 114 degree to plus 114 degree.

As a result, the boundaries of three laser bundles are:

  • Left bundle: plus 114 degree and plus 66 degree
  • Forward bundle: plus 24 degree and minus 24 degree
  • Right bundle: minus 114 degree and minus 66 degree

[math]\displaystyle{ \sin 2\pi x + \ln e }[/math]

These two equations will make sure the pico can find junction in thw widthest corridor and also could go through the junction in open loop. Finally, the detection radius is set to be 0.85.

Junction detection.jpeg


To increase the robust of the detection, all the distance of the laser line inside the laser bundle will be measured, if 80% laser line has longer distance than the detection radius, PICO will consider there is a junction.

door open detection

movement

door movement

Door movement.jpeg

junction movement

code snippet: junction_movement.cpp

move forward

Similarly to the junction_movement.cpp, move_forward.cpp uses three front laser sectors to adjust the speed. The forward speed is either 0.5m/s when the detection allows or -0.2 m/s otherwise. What differs from the junction_movement.cpp is that the forward movement will not stop when it adjusts with the side movement to avoid obstruction. With 6 laser sectors, 3 at both sides, it adjusts the sidewards speed. When it detects a obstruction, it will move sidewards to avoid the obstruction.

code snippet: move_forward.cpp

mapping

Mapping2.jpeg

protection

Potential field2.jpeg

open space

result

evaluation

Evaluation group9 EMC 2017

Code snippets

Movement

code snippet: move_forward.cpp
code snippet: junction_movement.cpp

Files